Strona 1 - IS15 Wind

MANUAL Simrad IS15 Wind

Strona 2

IS15 Wind Manual 8 20220752J There are three arrows at the top of the LCD indicating what data is being displayed at any one time. The arrow legend i

Strona 3 - 20220752J 1

Operation 20220752J 9 2.4 LCD Screens Use short presses on the left/right buttons to select the preferred screen as shown below. ScreenDisplay Sc

Strona 4 - Document history

IS15 Wind Manual 10 20220752J Screen 4 True Wind Angle and VMG This display is indicated by the left LCD arrow being lit, showing 'True' (W

Strona 5 - Contents

Operation 20220752J 11 Display Damping (d1-d4) Both the wind angle and the wind speed are controlled by the same damping function. There are four dam

Strona 6

IS15 Wind Manual 12 20220752J 2. Apply a short press on the button. The wind speed alarm limit screen is shown. 3. Press the button, hold for 2 s

Strona 7 - 1 INTRODUCTION

Operation 20220752J 13 Apparent Wind AngleTrue Wind AngleApparent Wind SpeedTrue Wind SpeedBoat SpeedWind DirectionN Figure 2-2 Apparent / True Wind

Strona 8 - 1.2 Optional equipment

IS15 Wind Manual 14 20220752J 3 OPERATION OF THE IS15 TACK The IS15 Tack has basically the same functions as IS15 Wind. The difference is the magni

Strona 9 - 2.1 General Description

Technical Specifications 20220752J 15 4 TECHNICAL SPECIFICATIONS 4.1 IS15 WIND (IS15 TACK) True and Apparent Wind Angle Functions Wind Angle Display

Strona 10 - 2.3 Display backlighting

IS15 Wind Manual 16 20220752J Display Backlighting Control Two independent lighting banks or individual settings (bank 0) Wind data Output via NME

Strona 11 - 2.4 LCD Screens

Technical Specifications 20220752J 17 4.2 Instrument Software Information V1R1: Beta version, not used in ordinary production. V1R2: First productio

Strona 12 - Sub screens

This page is intentionally left blank

Strona 13 - 20220752J 11

IS15 Wind Manual 18 20220752J Notes! 1. PCB Ass’y with this revision does not accept V1R2 or V1R4 software. 2. V1R6 is backward compatible with V1R

Strona 14 - 2.5 Alarm Sounding

Installation 20220752J 19 5 INSTALLATION 5.1 General This section provides detailed information required to successfully install an IS15 Instrument

Strona 15 - Operation

IS15 Wind Manual 20 20220752J 2. Carefully position the self-adhesive template provided on the surface where the display head is to be mounted. 3.

Strona 16 - 3 OPERATION OF THE IS15 TACK

Installation 20220752J 21 5.3 Wind Transducer Location The sensor must be mounted in the fore-aft direction, with the sensor forward of the mast so

Strona 17 - 4 TECHNICAL SPECIFICATIONS

IS15 Wind Manual 22 20220752J 6. When the wand is correctly in position, screw down the collar until it is HAND tight (2). 7. Lock the retaining cl

Strona 18 - Figure 4-1 IS15 Dimensions

Installation 20220752J 23 Use the Roblink Power Cable (P/N 22093587) for supply to connector no. 1. Cut off one of the plugs on the supplied 0,3 m (1

Strona 19 - 20220752J 17

IS15 Wind Manual 24 20220752J Speed/temp transducerDepthtransducerSupply 10,8-15,6VDCSIMRADWindTransducer*SIMRAD***IS15 Multi (Speed)SIMRADSIMRAD* *0

Strona 20 - 20220752J

Installation 20220752J 25 An example of a fully equipped IS 15 system is shown in Figure 5-5. See also the Interconnection – Principle diagram Figure

Strona 21 - 5 INSTALLATION

IS15 Wind Manual 26 20220752J Figure 5-6 Securing connectors to the instrument Make sure that all empty sockets have the protective bung inserted.

Strona 22

Installation 20220752J 27 NMEA connections general Note ! The NMEA port on the IS15 instruments is unidirectional, i.e. it is automatically configur

Strona 23 - 5.3 Wind Transducer

IS15 Wind Manual 20220752J 1 This manual is intended as a reference guide for installing and using the analog IS15 Wind and IS15 Tack instruments an

Strona 24 - Stand Alone system (W-1)

IS15 Wind Manual 28 20220752J Connecting a Simrad Robertson “X” series autopilot NMEA Out This connection will provide wind input to the autopilot. T

Strona 25 - Integrated systems

Installation 20220752J 29 Connecting to a Simrad XX32/XX40/XX50 series GPS Plotter NMEA out This will provide the chart plotter also with wind inform

Strona 26 - 24 20220752J

IS15 Wind Manual 30 20220752J 2. Refer to section 5.4 and connect one end of the supplied 10 m Roblink cable to one of the Roblink sockets in the Tr

Strona 27 - Securing the connectors

Setting-Up 20220752J 31 6 SETTING-UP 6.1 First Time Turn on Note ! Always turn on all NMEA “listeners” and “talkers” connected to the system before

Strona 28

IS15 Wind Manual 32 20220752J 6.2 Installation and Calibration Menu The installation menu is arranged as follows: Screen Display Screen 1 Scre

Strona 29 - Figure 5-9 NMEA in

Setting-Up 20220752J 33 Screen 1 ILLUM. BANK [bAn.1] The display reads bAn.0 – bAn.2 The IS15 instrument system can have two separate banks of instru

Strona 30

IS15 Wind Manual 34 20220752J Displayed Velocity Made Good units may be set to Knots, Miles Per Hour or Kilometres Per Hour. (This will be the same a

Strona 31 - 20220752J 29

Setting-Up 20220752J 35 Screen 6 SHOP MODE [SHOP] The instrument has a demonstration mode that can be activated by selecting ‘Shop’ On. This function

Strona 32

IS15 Wind Manual 36 20220752J Notes ! 1. The Roblink must be turned Off when the instrument is used as a single NMEA repeater. However, if more head

Strona 33 - 6 SETTING-UP

Fault Finding 20220752J 37 7 FAULT FINDING If the instrument is part of an IS15 instrument system including a Transceiver (IS15 Power Supply or Expan

Strona 34 - (manual calibration)

IS15 Wind Manual 2 20220752J Document revisions Rev Date Written by Checked by Approved by D 100300 NG ThH E 091100 NG ThH F 191200 NG ThH

Strona 35 - Screen 3

IS15 Wind Manual 38 20220752J Wind Display Faults Condition Probable Cause Action There are no Wind Speed or Wind Angle displays, or these displays a

Strona 36

Fault Finding 20220752J 39 Condition Probable Cause Action The Wind Angle displays are incorrect. The wind transducer is not connected to the IS15 Tr

Strona 37 - Screen 8

IS15 Wind Manual 40 20220752J 8 MAINTENANCE 8.1 General Maintenance Caution ! Do not use any abrasives, chemical cleaners, petrol or diesel to clea

Strona 38 - Screen 11

Maintenance 20220752J 41 8.4 Return for Service Prior to return please ensure that an instrument that is believed to be faulty is correctly installe

Strona 39 - 7 FAULT FINDING

IS15 Wind Manual 42 20220752J 9 SPARE PARTS LIST 22092100 IS15 Wind Instrument 22092704 IS15 Wind PROM (programmed) V..R.. 20220794 IS15 Wind/Tack Op

Strona 40

IS15 Wind Manual 20220752J 3 Contents 1 INTRODUCTION ...5 1.1 Th

Strona 41 - 20220752J 39

IS15 Wind Manual 4 20220752J This page is intentionally left blank.

Strona 42 - 8 MAINTENANCE

Introduction 20220752J 5 1 INTRODUCTION 1.1 The Basic IS15 Wind System (W-1) A basic stand alone Wind System comprises the following: • IS15 Wind i

Strona 43 - 8.5 Local Master Reset

IS15 Wind Manual 6 20220752J 1.2 Optional equipment • IS15 Cable 2 m (6,5’) P/N 22093728 • IS15 Cable 5 m (16’) P/N 22092548 • IS15 Cable 10 m (3

Strona 44 - 9 SPARE PARTS LIST

Operation 20220752J 7 2 OPERATION OF IS15 WIND INSTRUMENT 2.1 General Description The display is divided into two sections, the scale with pointer,