Transducerinstallation
Figure10Mountingandclampingrings
A
B
C
D
E
F
G
(CD016004A)
AMountingring(tobeweldedtotheretractablekeel)
BClampingring
CGuidancenotchinthemountingring.ThisnotchmustbepointingUP!
DM6guidanceboltonthemountingring.
EM6guidanceholeontheclampingring,willensurethattheclampingring
tscorrectlyonthemountingring.
FHoleforoneofthe12mountingbolts.
GSelf-lockingthreadtoacceptthemountingbolt.
Mountingthearray
1Weldthemountingringtotheretractablekeel.Ensurethatthenotchonthe
mountingringpointsUP.
Specialcaremustbetakentoensurethatthemountingringisweldedcorrectly
inplace.
Checkandverifythatthemountingringisvertical.
Checkandverifythattheringisnottwistedoutofshapeasaresultofthewelding.
2Liftthetransducer,andplaceitintothemountingring.Ensurethatthearrowon
thetransducerrimpointsUP .
3Fittheclampingring,andmountthe12bolts.
Bolttype:M12x55StainlesssteelA4Class80
Washer:Flat,StainlesssteelA4Class80
Torque:76Nm
ApplyLocktite243
331549/B