Simrad TRANSDUCER - INSTALLATION GENERIC REV H Instrukcja Instalacji Strona 110

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 212
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 109
SimradMS70
[R]Powercablestoship’s230Vacmainssupply
ThepowercablesprovidedtosupplytheTransceiverUnitwith230V acmainsare
connectedtothefourcircuitbreakersinthebottomoftherack.
Circuitbreakers
CircuitBreaker0(left):FeedsDistributor0(bottom),forfutureexpansions
CircuitBreaker1:FeedsDistributor1(middle),powersTRCbeamformingcomputers
0,1and2
CircuitBreaker2:FeedsDistributor2(top),powersTRCbeamformingcomputers3,4
and5andtheEthernetSwitch
CircuitBreaker3(right):Feedsthemainfanunitatthebottomoftherack
Theotherendofthemainscablesarettedwithastandardmainsplug.
Table8Powercablestoship’ smains
Cable
FromTo
R1
Ship’smainssupplyCircuitbreaker0
R2
Ship’smainssupplyCircuitbreaker1
R3
Ship’smainssupplyCircuitbreaker2
R4
Ship’smainssupplyCircuitbreaker3
AllcablesareprovidedbyKongsbergMaritime.
Relatedtopics
Powercables;TransceiverUnitonpage88
Circuitbreakeronpage146