Simrad AP24 Instrukcja Instalacji Strona 24

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 32
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 23
Technical specifications | 23
4.2 AP24 Control Unit
Dimensions:.....................................................See Figure 4-1
Weight: ..........................................................0,3 kg (0,7 lbs)
Material:........... Front: Black ABS+PC, Back: Dark gray ABS+GF
Supply and interface: .......................................12V via SimNet
Power consumption....................................................... 1,2 W
SimNet Network load factor (NL): ..........................................2
SimNet ports (input/output): ................................................2
Display:
Type:.....................................Backlit LCD matrix display
Resolution:............................................130 x 79 pixels
Illumination (Red or white):........... Adjustable in 10 steps
Safe distance to compass: ................................. 0.3 m (1.0 ft.)
Environmental Protection:..........IP56 from front, IP43 from back
Temperature:
Operating:........................0 to +55 °C (+32 to +130 °F)
Storage:........................–30 to +70 °C (–22 to +158 °F)
Figure 4-1 AP24 Control Unit – dimensions
(Mounting bracket is optional equipment)