10 | Operation
2.5 SG05 Gateway installation
• The SG05 is bulkhead mounted by the enclosed
screws. The SimNet connectors must be pointing
downwards. Figure 2-3.
• Connect other uni
ts according to Figure 2-1. Use only
readymade S
imNet cables and accessories. For
SimNet network termination refer to section 2.9 on
page 15.
• Connect 12V SimNet supply. Refer to Figure 2-10 for
correct pol
arity
• Connect the 1 m pigtail plug into mating connector of
the Volvo Penta Autopilot Interface. Figure 2-4
SG05 has a built in LED that will alternate with 1 Hz when
the unit is up running.
Figure 2-3 SG05 mounting
Simrad SG05
Gateway
Autopilot Interface kit
(Volvo Penta part number 3819744)
Autopilot
Gateway
EVC connect point
Y-split
cable
Figure 2-4 SG05 connection to Volvo Penta Autopilot Interface