FS 20/25 Operators Manual 901-10037001/1.1
FS 20/25 Installation, System Set-Up and Test Page 4.11
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
4.4.2 Power-Up Configuration
For the system to operate properly, the trawl unit configuration must be selected
correctly. In addition, modification of these power-up configuration parameters is
done in a special mode selected after power-up of the HP/PC processor unit.
The following sections describe the process of configuring these parameters. These
steps must be followed only when the system is powered-up for the first time or when
you have to replace the HP/PC processing unit or the TTM Module assembly.
4.4.3 FS 20Start-up Procedure
For the purpose and demonstration on the Start-up Procedure in this chapter, we
are using an HP/PC processing unit that has only 2 Com ports, Com 1 and Com 2.
The Com 1 port from the HP/PC processing unit is connected to the FS20/25 TTM
module RS 232 port “A”. No connection is made to the Com 2 or to the “B” port of
the TTM module.
We will be using a TS15 S 330kHz Trawl Sonar Head with the 200kHz net sounder
option and an FS3300 sensor module.
The first step after a successful power up is to configure the system for the desired
“User Setting” operating mode and set-up, if not already done; you will automatically
select “Generic”. Clicking on “Generic” or clicking on specific types of fishery does
this. Refer to the following window.