Simrad EQ 55 Dokumentacja Strona 38

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 60
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 37
/PTIONALCONNECTIONS
)3$ATALINE$ATABOX
EQ32 MKII NMEA Data Box
0IN
1White TX A (DATA OUT) + Radio nav input
2Brown TX B (RETURN) -
3YellowRX A (DATA IN) WHT NMEA bus to
4 Green RX B (RETURN) GRN repeaters
%XTERNALPOSITIONHEADINGANDSPEED
EQ32 MKII NMEA
0IN
3YellowRX A (DATA IN) NMEA0183
4 Green RX B (RETURN)
0OWERSUPPLYCONNECTIONS - The internal voltage regulator will al-
low the EQ32 MKII to operate normally over the power supply voltage
range from 10 to 32 Vdc. Connections between the EQ32 MKII and the
external power supply are accomplished by means of the supplied power
cable, which is approximately 1.5 meters long.
After connecting the cable to the power source, push the plug as far as it
will go into the two pin receptacle marked PWR on the rear of the cabi-
net and turn the plugs coupling ring clockwise until it clicks into locked
position.
&USE - Warning! Using a fuse which is not specified for your equip-
ment can cause it to blow the instant the EQ32 MKII has been switched
on or it will not protect the equipment in the event of trouble.
4RANSDUCERCONNECTION - A 10 meter cable is supplied for connec-
tion between the transducer and the display cabinet - EQ32 MKII. Push
the female plug, as far as it goes, into the receptacle marked ECHO on
the rear of the cabinet and turn the plugs coupling ring clockwise until it
#HAPTER %1-+)))NSTALLATIONANDSERVICE